We Are Open 24 Hours a Day, 7 Days a Week, Including Weekends and Public Holidays.
1.Keywords
Biofilter Odor Control System, Biological Waste Gas Treatment, Microbial Deodorizer, Organic VOCs Degradation Unit, Biotrickling Filter, Eco-Friendly Odor Removal, Industrial Bio-Scrubber, Sewage Plant Deodorization, Composting Odor Control, Chemical-Free Air Purification
2.Technical Specifications
1. Core Performance Parameters
Parameter |
Specification |
Odor Removal Rate |
85-99% (Dependent on compound) |
Empty Bed Residence Time (EBRT) |
15-60 seconds |
Pressure Drop |
50-200 Pa |
Operating Temperature |
10-45°C (Optimal 20-35°C) |
pH Range |
6.0-8.0 (Adjustable dosing system) |
Moisture Content |
40-60% (Biofilm carrier) |
2. Target Pollutants & Removal Efficiency
Odor Compound |
Removal Efficiency |
Microbial Strain |
H₂S (Hydrogen Sulfide) |
>95% |
Thiobacillus |
NH₃ (Ammonia) |
90-98% |
Nitrosomonas |
VOCs (Toluene, Xylene) |
80-95% |
Pseudomonas |
Mercaptans |
85-92% |
Hyphomicrobium |
3.System Components
1. Biofilter Bed
Filter Media:
Organic (Coconut fiber, peat, bark)
Inert (PVC rings, ceramic pellets)
Layering:
3-stage stratified design (Pre-treatment, Main degradation, Polishing)
2. Microbial Culture
Customized Strains:
Pre-acclimated cultures for specific industries
Dormant spores for cold-start conditions
3. Support Systems
Humidity Control:
Ultrasonic misting + drainage layer
Nutrient Dosing:
Automated NPK injection (PLC-controlled)
4.Design Advantages
1. Energy Efficiency
Zero Chemicals: Fully biological process
Low Power: <0.5 kW per 1000m³/h airflow
2. Smart Operation
IoT Monitoring:
Real-time VOC sensors + cloud data logging
Self-Regulating:
Adaptive water spray based on bed moisture
3. Modular Construction
Standard Modules:
1m×1m×2m (1000m³/h capacity per unit)
Expandable:
Parallel connection for large flow rates
5.Industry Applications
A. Wastewater Treatment
Sewage Lift Stations: H₂S >95% removal
Sludge Dryers: NH₃ & amine control
B. Food Processing
Fish Meal Plants: Trimethylamine degradation
Rendering Facilities: Fatty acid VOC removal
C. Agricultural
Livestock Barns: Manure odor elimination
Composting Sites: Complex sulfur/organic mix
D. Chemical Industry
Pharmaceuticals: Ether/ester compound treatment
Pulp & Paper: Mercaptan reduction
6.Certifications & Testing
Performance Verified:
EN 13725 (Olfactometry testing)
EPA TO-14A (VOC analysis)
Safety Standards:
ATEX Zone 2 (Explosive atmospheres)
ISO 14001 Environmental Management
7.Custom Options
✓ Cold-climate heated enclosures
✓ Hybrid system (Biofilter + Activated Carbon)
✓ Mobile units for temporary odor control
(Provide odor concentration & composition for microbial strain selection)
8.Contact for
Pilot testing with on-site gas sampling
Biofilm inoculation services
O&M training programs
Indirizzo